Orient New Life Medical Co.,Ltd.

 

Quality is life.

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsDrug Abuse Test Kit

Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml

I'm Online Chat Now
Certification
China Orient New Life Medical Co.,Ltd. certification
China Orient New Life Medical Co.,Ltd. certification
We are satisfied with your quality & services so far. The HIV 1/2 antibody Test performance is perfect.

—— Katrina

I have to say that New Life provides high quality products. The FOB, Troponin I, HIV, HCV, Drug Abuse test all performed very well in our market.

—— Clemen

Your Dengue IgG/IgM and Malaria test perfromed well. Now we want to try your Filariasis test in our market.

—— Primo

Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml

Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml
Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml

Large Image :  Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml Get Best Price

Product Details:
Place of Origin: China
Brand Name: New Life
Certification: ISO13485, CE
Model Number: LSD STRIP
Payment & Shipping Terms:
Minimum Order Quantity: 5000pcs
Price: USD0.5-USD5
Packaging Details: 1pc/pouch, 25pcs/box
Delivery Time: 20-30days
Payment Terms: T/T, Western Union
Supply Ability: 2000000pcs/month
Detailed Product Description
Category: Drug Abuse TESGTING Kits Format: STRIP LSD 3mm
Specimen: Urine Testing Time: 5 Minu
Shelf Life: 24 Months Application: LSDl Drug Test Strip
Cut-off: 20ng/ml
High Light:

drug test strips

,

accurate drug test kits

Drug Abuse Test Kit Lysergic Acid Rapid Test 3mm strip ,high sensitivity cut-off 20ng/ml

 

Product Name

 

LSD ( Lysergic Acid) Rapid Diagnostic Test

Specimen: Urine

 

Background

 

Lysergic acid diethylamide (LSD) is a white powder or a clear, colorless liquid. LSD is manufactured from lysergic acid which occurs naturally in the ergot fungus that grows on wheat and rye. It is a Schedule I controlled substance, available in liquid, powder, tablet (microdots), and capsule form. LSD is recreationally used as a hallucinogen for its ability to alter human perception and mood. LSD is primarily used by oral administration, but can be inhaled, injected, and transdermally applied. LSD is a non-selective 5-HT agonist, may exert its hallucinogenic effect by interacting with 5-HT 2A receptors as a partial agonist and modulating the NMDA receptor-mediated sensory, perceptual, affective and cognitive processes. LSD mimics 5-HT at 5-HT 1A receptors, producing a marked slowing of the firing rate of serotonergic neurons. LSD has a plasma half-life of 2.5-4 hours. Metabolites of LSD include N-desmethyl-LSD, hydroxy-LSD, 2-oxo-LSD, and 2-oxo-3-hydroxy-LSD .These metabolites are all inactive. LSD use can typically be detected in urine for periods of 2-5 days.

 

The LSD Rapid Test Panel (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Lysergic Acid Diethylamide in urine. The LSD Rapid Test Panel (Urine) yields a positive result when Lysergic Acid Diethylamide in urine exceeds 20 ng/mL.

 

 

 

 

Test Principle

 

The FYL Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

During testing, a urine specimen migrates upward by capillary action. Fentanyl, if present in the urine specimen below 20 ng/mL, will not saturate the binding sites of antibody-coated particles in the test device. The antibody-coated particles will then be captured by immobilized FYL conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the FYL level exceeds 20 ng/mL because it will saturate all the binding sites of anti-FYL antibodies.

 

A drug-positive urine specimen will not generate a colored line in the test line region, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

 

SPECIMEN COLLECTION AND STORAGE

 

The urine specimen must be collected in a clean and dry container. Urine collected at any time of the day may be used. Urine specimens exhibiting visible particles should be centrifuged, filtered, or allowed to settle to obtain clear specimen for testing. Specimen.

 

Urine specimens may be stored at 2-8°C for up to 48 hours prior to testing. For long-term storage, specimens may be frozen and stored below -20°C. Frozen specimens should be thawed and mixed before testing.

 

 

STORAGE

 

Store as packaged in the sealed pouch either at room temperature or refrigerated (2-30°C). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.

 

LIMITATION

 

1. The 6-MAM Rapid Test Cassette provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrophotometry (GC/MS) is the preferred confirmatory method2.3.

2. It is possible that technical or procedural errors, as well as other interfering substances in the urine specimen may cause erroneous results.

3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.

4. A positive result indicates presence of the drug or its metabolites but does not indicate level of intoxication, administration route or concentration in urine.

5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.

 

performance characteristics

 

A side-by-side comparison was conducted using the Rapid Test Cassette (Urine) and GC/MS. The following results were tabulated:

 

 

 

 

Norfentanyl Percent of n Visual Result
Concentration (ng/mL) Cut-off Negative Positive
 
0 0% 30 30 0
10 -50% 30 30 0
15 -25% 30 27 3
20 Cut-off 30 15 15
25 +25% 30 3 27
30 +50% 30 0 30
60 +300% 30 0 30
  Analytical Specificity    

 

Lysergic Acid Rapid Test 3mm Strip , High Sensitivity Cut - Off 20ng/Ml 0

 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

Contact Details
Orient New Life Medical Co.,Ltd.

Contact Person: Jerry Meng

Tel: +8618657312116

Send your inquiry directly to us