Orient New Life Medical Co.,Ltd.

 

Quality is life.

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsDrug Abuse Test Kit

Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml

I'm Online Chat Now
Certification
China Orient New Life Medical Co.,Ltd. certification
China Orient New Life Medical Co.,Ltd. certification
We are satisfied with your quality & services so far. The HIV 1/2 antibody Test performance is perfect.

—— Katrina

I have to say that New Life provides high quality products. The FOB, Troponin I, HIV, HCV, Drug Abuse test all performed very well in our market.

—— Clemen

Your Dengue IgG/IgM and Malaria test perfromed well. Now we want to try your Filariasis test in our market.

—— Primo

Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml

Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml
Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml

Large Image :  Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml Get Best Price

Product Details:
Place of Origin: China
Brand Name: New Life
Certification: ISO13485, CE
Model Number: MQL STRIP
Payment & Shipping Terms:
Minimum Order Quantity: 5000pcs
Price: USD0.5-USD5
Packaging Details: 1pc/pouch, 25pcs/box
Delivery Time: 20-30days
Payment Terms: T/T, Western Union
Supply Ability: 2000000pcs/month
Detailed Product Description
Category: Drug Abuse TESGTING Kits Format: Cassette MQL 4mm
Specimen: Urine Testing Time: 5 Minu
Shelf Life: 24 Months Application: Mql Drug Test Strip
Cut-off: 300ng
High Light:

drug test strips

,

accurate drug test kits

Drug Abuse Test Kit Methaqualone Rapid Test 4mm cassette ,high sensitivity cut-off 300ng/ml

 

Product Name

 

MQL ( Methaqualone) Rapid Diagnostic Test

Specimen: Urine

 

 

Intended Use

 

The MQL Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the qualitative detection of Methaqualone in human urine at a cut-off concentration of 300 ng/mL.

This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Parameter Calibrator Cut-off (ng/mL)
MQL Methaqualone 300

 

 

 

Test Principle

 

 

The MQL Rapid Test Panel (Urine) is a a rapid chromatographic immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

During testing, a urine specimen migrates upward by capillary action. Methaqualone, if present in the urine specimen below 300 ng/mL, will not saturate the binding sites of antibody-coated particles in the Test Panel. The antibody-coated particles will then be captured by immobilized Methaqualone conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Methaqualone level exceeds 300 ng/mL because it will saturate all the binding sites of anti-Methaqualone antibodies.

 

A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region.

 

To serve as a procedural control, a colored line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.

 

 

DIRECTIONS FOR USE

 

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, color will migrate across the membrane.

Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

 

 

INTERPRETATION OF RESULTS

 

 

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

 

 

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

 

 

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

 

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

 

QUALITY CONTROL

 

A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

 

performance characteristics

 

A side-by-side comparison was conducted using the Rapid Test Cassette (Urine) and GC/MS. The following results were tabulated:

 

 

Table 1: Specimen Correlation

 

 

Method   GC/MS Total
    Results Positive Negative Results
MQL Rapid Test Panel   Positive 79 11 90
    Negative 9 151 160
Total Results     88 162 250
% Agreement with GC/MS 89.8% 93.2% 92.0%
    Analytical Sensitivity    


Methaqualone Rapid Test 4mm Cassette Drug Abuse Test Kit Cut Off 300ng/Ml 0

 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

Contact Details
Orient New Life Medical Co.,Ltd.

Contact Person: Jerry Meng

Tel: +8618657312116

Send your inquiry directly to us