Orient New Life Medical Co.,Ltd.

 

Quality is life.

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsInfectious Disease Blood Tests

Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE

Certification
Good quality Home Testing Kits for sales
Good quality Home Testing Kits for sales
We are satisfied with your quality & services so far. The HIV 1/2 antibody Test performance is perfect.

—— Katrina

I have to say that New Life provides high quality products. The FOB, Troponin I, HIV, HCV, Drug Abuse test all performed very well in our market.

—— Clemen

Your Dengue IgG/IgM and Malaria test perfromed well. Now we want to try your Filariasis test in our market.

—— Primo

I'm Online Chat Now

Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE

China Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE supplier
Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE supplier Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE supplier

Large Image :  Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE

Product Details:

Place of Origin: China
Brand Name: New Life
Certification: ISO13485,CE

Payment & Shipping Terms:

Minimum Order Quantity: 5000pcs
Price: USD0.15-USD1
Packaging Details: 1pc/pouch, 25pcs/box
Delivery Time: 20-30days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 2000000pcs/month
Contact Now
Detailed Product Description
Category: Infectious Format: Strip/cassette
Specimen: Swab Testing Time: 5-15 Minutes
Shelf Life: 24 Months Application: Rotavirus
Accuracy: 99.51%

gold colloidal method Rotavirus Rapid Diagnostic Cassette to detect rotavirus in human feces ,, easily and quick

 

Product Name:


Rotavirus Rapid Diagnostic test

 

 

Intended Use:

 

The Rotavirus Rapid Test Device (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of rotavirus in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of rotavirus infection.

 

Test Principle:

 

The Rotavirus Rapid Test Device (Feces) has been designed to detect rotavirus through visual interpretation of color development in the internal strip. The membrane was immobilized with anti-rotavirus antibodies on the test region. During the test, the specimen is allowed to react with colored anti-rotavirus antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough rotavirus in specimens, a colored band will form at the T region of the membrane. Presence of colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.

 

 

 

TEST PROCEDURE

 

Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.

 

Specimen collection and pre-treatment:

 

Use the specimen collection container for specimen collection. Best results will be obtained if the assay is performed within 6 hours after collection.

 

For solid specimens: Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea).

 

For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 50 µL) into the specimen collection tube containing the extraction buffer.

 

Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube.

Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation.

 

 

 

 

Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window.

 

As the test begins to work, you will see color move across the membrane.

Wait for the colored band to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

 

 

Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S) of a new test device and start afresh following the instructions mentioned above.

 

 

INTERPRETATION OF RESULTS

 

 

POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

 

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

 

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

PERFORMANCE CHARACTERS:

 

Table: Rotavirus Rapid Test vs. Latex Agglutination

 

Relative Sensitivity: 99.1% (96.8%-99.9%)*

Relative Specificity: >99.9% (97.7%-100.0%)*

Overall Agreement: 99.5% (98.1%-99.9%)*

*95% Confidence Interval

 

Rotavirus

Rapid Test

 
+ - Total
Latex Agglutination + 224 2 226
- 0 156 156
  224 158 382

 

 

 

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for the control line failure. Review the procedure and repeat the test with a new device. If problem persists, please contact your local distributor.

 

 

 

 

Swab Specimen Rotavirus Test Kit 99% Accuracy Apid Visual Immunoassay With CE

 
ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

 

Contact Details
Orient New Life Medical Co.,Ltd.

Contact Person: Jerry Meng

Send your inquiry directly to us (0 / 3000)