Orient New Life Medical Co.,Ltd.

 

Quality is life.

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsDrug Abuse Test Kit

Quick Diagnostic Drug Abuse Test Kit , CE Instant Drug Test Kits Strip Format

Certification
Good quality Home Testing Kits for sales
Good quality Home Testing Kits for sales
We are satisfied with your quality & services so far. The HIV 1/2 antibody Test performance is perfect.

—— Katrina

I have to say that New Life provides high quality products. The FOB, Troponin I, HIV, HCV, Drug Abuse test all performed very well in our market.

—— Clemen

Your Dengue IgG/IgM and Malaria test perfromed well. Now we want to try your Filariasis test in our market.

—— Primo

I'm Online Chat Now

Quick Diagnostic Drug Abuse Test Kit , CE Instant Drug Test Kits Strip Format

China Quick Diagnostic Drug Abuse Test Kit , CE  Instant Drug Test Kits Strip Format supplier
Quick Diagnostic Drug Abuse Test Kit , CE  Instant Drug Test Kits Strip Format supplier Quick Diagnostic Drug Abuse Test Kit , CE  Instant Drug Test Kits Strip Format supplier

Large Image :  Quick Diagnostic Drug Abuse Test Kit , CE Instant Drug Test Kits Strip Format

Product Details:

Place of Origin: China
Brand Name: New Life
Certification: ISO13485, CE
Model Number: strip

Payment & Shipping Terms:

Minimum Order Quantity: 5000pcs
Price: USD0.5-USD5
Packaging Details: 1pc/pouch, 25pcs/box
Delivery Time: 20-30days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 2000000pcs/month
Contact Now
Detailed Product Description
Category: Drug Abuse Kits Format: Strip
Specimen: Urine Testing Time: 5-15 Minutes
Shelf Life: 24 Months Application: KET
Cut-off: 1000ng/ml

Drug Abuse Test Kit KET Rapid Diagnostic Test strip, professional package, 1000ng/ml cut-off, Ketamine urine drug test

Product Name

 

KET (Ketamine ) Rapid Diagnostic Test Strip

Specimen: Urine

 

 

Product Cat No Specimen Sensitivity Format Kit Size
KET YD161S3 Urine 1000 ng/mL 3mm Strip 100T
YD161C4 4mm Cassette 25T

 

 

Intended Use

 

The KET Rapid Test Strip (Urine) is a rapid chromatographic immunoassay for the detection of Ketamine in human urine at a cut-off concentration of 1,000ng/mL. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Parameter Calibrator Cut-off (ng/mL)
KET (Ketamine ) Ketamine 1000

 

 

 

Test Principle

 

 

Ketamine is a dissociative anesthetic developed in 1963 to replace PCP (Phencyclidine). While Ketamine is still used in human anesthesia and veterinary medicine, it is becoming increasingly abused as a street drug. Ketamine is molecularly similar to PCP and thus creates similar effects including numbness, loss of coordination, sense of invulnerability, muscle rigidity, aggressive / violent behavior, slurred or blocked speech, exaggerated sense of strength, and a blank stare. There is depression of respiratory function but not of the central nervous system, and cardiovascular function is maintained. The effects of Ketamine generally last 4-6 hours following use. Ketamine is excreted in the urine as unchanged drug (2.3%) and metabolites (96.8%).1 The KET Rapid Test Dipstick (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Ketamine in urine. The KET Rapid Test Dipstick (Urine) yields a positive result when Ketamine in urine exceeds 1,000ng/mL.

 

 

DIRECTIONS FOR USE

 

  1. Bring the pouch to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
  2. With arrows pointing towards the urine specimen, immerse the Test Dipstick vertically in the urine specimen in such a way that urine does not cross MAX line on the Test Dipstick for 10-15 seconds. See the illustration below.
  3. Wait for the color line(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

 

 

INTERPRETATION OF RESULTS

 

 

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

 

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

 

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

 

 

 

 

LIMITATION

 

 

  1. The KET Rapid Test Dipstick (Urine) provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method.
  2. It is possible that technical or procedural errors, as well as other interfering substances in the urine specimen may cause erroneous results.
  3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.
  4. A positive result indicates presence of the drug or its metabolites but does not indicate level of intoxication, administration route or concentration in urine.
  5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.
  6. This test does not distinguish between drugs of abuse and certain medications.

 

 

 

PERFORMANCE

 

 

Accuracy

 

A side-by-side comparison was conducted using The KET Rapid Test Dipstick and a commercially available KET rapid test. Testing was performed on 105 clinical specimens previously collected from subjects present for Drug Screen Testing. The following results were tabulated:

 

Method     GC/MS Total Results
KET Rapid   Results Positive Negative  
  Positive 77 3 80
Test Dipstick  
  Negative 2 168 170
   
Total Results 79 171 250
% Agreement 97.5% 98.2% 98.0%

 

 